Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Journal of Medical Biomechanics ; (6): E085-E090, 2022.
Article in Chinese | WPRIM | ID: wpr-920673

ABSTRACT

Objective To establish the instability model of goat cervical vertebrae, and test biomechanical stability of the novel arc cervical titanium mesh with endplate ring. Methods The anatomical data from cervical vertebrae of adult goats were measured, so as to select a new type of arch cervical titanium mesh with endplate ring which was suitable for goat cervical vertebrae. A total of 24 goats with preserved articular capsule, ligaments and intervertebral disc were randomly divided into 4 groups. Group A (n=6, normal group) didn’t receive any special treatment, while Group B (n=6, model group) received partial resection of C4 vertebrae as well as upper and lower intervertebral disc. On the basis of models in Group B, Group C (n=6, experimental group) was installed with the novel arch cervical titanium mesh and fixed by plate and screw, and Group D (n=6,control group) was installed with traditional straight titanium mesh and fixed by plate and screw. The ranges of motion (ROMs) for 4 groups of specimens during flexion, extension, left/right lateral bending, left/right rotation under 2.0 N·m load were measured, and their three-dimensional (3D) motion stability was tested. The displacement of Group C and Group D under 200 N compression force was measured, the stiffness was calculated, and the anti settlement ability of the whole specimen was tested. Results The ROMs of Group A in all directions were smaller than those of Group B,the ROMs of Group A were larger than those of Group C, and the ROMs of Group C during flexion were smaller than those of Group D (P<0.05). The stiffness of Group C was higher than that of Group D (P<0.05).The compression displacement of Group C was smaller than that of Group D(P<0.05). Conclusions Compared with the straight titanium mesh, the novel arc titanium mesh is more consistent with the physiological curvature of cervical verebrae, and has better stability than the traditional titanium mesh during the most frequent flexion activities of cervical verebrae. Moreover, compression displacement of the novel arc titanium mesh under short-term stress is smaller than that of the straight titanium mesh, and its postoperative anti-settlement is better than that of the straight titanium mesh, which is worthy of further experiment and clinical promotion.

2.
Chinese Journal of Burns ; (6): 85-90, 2020.
Article in Chinese | WPRIM | ID: wpr-799480

ABSTRACT

Objective@#To explore the choice of the donor site of flap and the repair method of secondary wound of flap donor site in tissue repair and reconstruction operation.@*Methods@#From January 2014 to September 2018, 62 cases of scar contracture deformity, 15 cases of skin tumor, 20 cases of skin and soft tissue injury, and 25 cases of chronic wound were admitted to the Burn Center of People′s Liberation Army of First Affiliated Hospital of Air Force Medical University, with 84 males and 38 females, aged from 3 to 89 years. Four repair strategies adopted for tissue repair and reconstruction and good repair of the donor site of flap were as follows: designing the flap rationally according to the condition around the wound or the size and shape of wound, choosing pre-expanded technique of the donor site of flap for repair of scar deformity optimally, making full use of the surrounding condition of flap donor site, and repaired with the distal flap, i. e. replacing the important site with secondary site. The donor site of flap was repaired by direct suture or peripheral flap and distal flap. The wound size of patients ranged from 3.0 cm×2.0 cm to 20.0 cm×18.0 cm, and the flap area ranged from 3.5 cm×2.0 cm to 25.0 cm×22.0 cm. The survival condition of flap, healing condition of donor site and recipient site, and follow-up condition of donor site and recipient site were recorded.@*Results@#Wounds of 122 patients were repaired with a total of 148 flaps designed by the above four repair strategies. All the flaps survived well, and the wound and flap donor site healed well. Follow-up for 3 to 36 months showed that the shape and function of recipient site and flap donor site were satisfactory.@*Conclusions@#According to the specific condition of the wound and anatomical structure of the surrounding tissue of flap donor site, overall surgical design with flexibility and personalization can achieve effects of good repair of the wound and reduce the secondary damage of flap donor site.

3.
Chinese Journal of Burns ; (6): 513-515, 2018.
Article in Chinese | WPRIM | ID: wpr-807196

ABSTRACT

Objective@#To investigate the effects of ultrathin abdomen flap in repairing deep electric burn wounds in finger of pediatric patients.@*Methods@#A total of 14 pediatric patients with simple electric burns in finger were admitted to our unit from March 2013 to October 2017. Six patients had electric burns in one finger, 5 patients had electric burns in two fingers, and 3 patients had electric burns in three fingers. The size of wounds in single finger ranged from 2.0 cm×1.0 cm to 3.5 cm×2.0 cm. After complete preoperative examination, wounds debridement and ultrathin abdomen flap repair operation were performed on 3 to 6 days post injury. Six pediatric patients were treated with abdominal random flap, 4 patients were treated with inferior epigastric artery paraumbilical perforator bilobed flap, and the other 4 patients were treated with superficial circumflex iliac artery bilobed flap. The size of flaps ranged from 4.0 cm×2.0 cm to 8.0 cm×4.0 cm. The donor sites were sutured directly.@*Results@#The flaps of 14 pediatric patients survived well after operation, and no flap showed blood supplying disorder. During follow-up of 3 to 24 months, the appearance and function of fingers were good, and the donor sites recovered well, with no cicatrix contracture deformity.@*Conclusions@#The ultrathin abdomen flap is one of the good choices for repairing deep electric burn wounds in finger of pediatric patients.

4.
International Journal of Laboratory Medicine ; (12): 1969-1970,1973, 2014.
Article in Chinese | WPRIM | ID: wpr-599627

ABSTRACT

Objective To explore the correlation between myeloperoxidase(MPO) and white blood cell (WBC) and other related numerical values in blood .Methods 50 common patients were randomly selected .The two blood samples in each patient were re-spectively collected by the biochemical tube anticoagulated by heparin sodium and the blood routine tube anticoagulated by ethylene diamine tetraacetic acid kalium(EDTA-K2 ) .Then plasma MPO content and WBC count ,absolute neutrophils count ,percentage of neutrophils ,platelet count in whole blood were detected .The MPO content and the above 4 items of detection results were per-formed the correlation analysis .Results The correlation coefficients(r) between plasma MPO with WBC count ,neutrophils count , percentage of neutrophils and platelet count in whole blood were 0 .253 ,0 .220 ,0 .111 and 0 .133 respectively ,which indicating that no correlation existed between them .Conclusion Blood MPO is mainly derived from polymorphonuclear neutrophils ,but WBC count ,neutrophils count and platelet count in whole blood do not cause the change of the myeloperoxidase content .

5.
Chinese Traditional and Herbal Drugs ; (24)1994.
Article in Chinese | WPRIM | ID: wpr-575212

ABSTRACT

Objective To establish HPLC method for assaying total flavonoids from the roots of Daphne genkwa(TFRD) in serum of mice and to elucidate the effect of mice serum containing TFRD on cell immunity in mice.Methods TFRD Concentration in serum was determined from the mice received single ig TFRD at certain time intervals using HPLC method.The effects of TFRD serum on lymphocyte proliferation,killing activities of NK and LAK cell,and phagocytic activity of macrophage were detected by MTT method.Results TFRD in serum reached its highest concentration in 20—30 min after ig admi-(nistration.) TFRD-containing serum significantly improved the proliferation of lymphocyte,enhanced the killing activities of NK and LAK cells,and enforced the phagocytic activity of macrophage.Conclusion(TFRD-)containing serum is an effective agents for enhancing cell immunity in mice.

SELECTION OF CITATIONS
SEARCH DETAIL